The power of AM series diode laser is up to 200W / bar. The working life, environmental adaptability and storage time of semiconductor lasers are greatly improved.
AM series diode laser adopts hard solder AuSn and heat sink material with matching thermal expansion coefficient, which effectively avoids the defects of indium such as thermal fatigue, electrothermal migration, and oxidation. At present, the power output of this series of products will be upgraded to 250W / bar, and the packaging height of a single bar will be reduced to 2.38mm..
Wavelength:940nm
Power: 200W/Bar
AuSn Packaging
Highpower
Low package height
Horizontal/Vertical stacking
Applications:
Cladding
Pump
Industrial Processing
- Avoid eye and skin exposure to direct radiation during operation.
- ESD precautions must be taken during storage, transportation and operation.
- Short-circuit is required between pins during storage and transportation.
- Use constant current power supply to avoid surge current during operation.
- Laser diode must be used according to the specifications.
- Laser diode must work with good cooling.
- Operation temperature ranges from 20℃ to 30℃ .
- Storage temperature ranges from 0℃ to +55℃.
Minimum Order Quantity: 1 Piece/Pieces
Payment Terms: T/T
Supply Ability: 100,000/year
Specifications ( 25°C ) | Unit | E2Y-940.3-200C-H03.1(3×1) | |||
Minimum | Typical | Maximum | |||
Optical Data ⑴ | Working Mode | . | cw | ||
Central Wavelength | nm | 940±3 | |||
Output Power Per Bar | W/bar | 200 | 220 | ||
Bar Numbers | pcs | 3 | |||
Bandwidth(FWHM) | nm | 3 | 5 | ||
Fast Axis Divergence with FAC (90% power) | mrad | 8 | 10 | ||
Slow Axis Divergence (95% power) | deg | 7.5 | 9 | ||
Electrical Data | Threshold Current | A | 23 | 28 | |
Operating Current | A | 205 | 215 | ||
Operating Voltage | V/bar | 1.6 | 1.8 | ||
Slope | W/A | 3.0 | 3.1 | ||
Efficiency | % | 55 | 60 | ||
Bar Specification | Number of Emitters | pcs | 25 | ||
Emitter Width | μm | 200 | |||
Emitter Pitch | μm | 400 | |||
Filling Factor | % | 50 | |||
Others | Pressure | bar | <5 | ||
Flow Rate | L/min/bar | 0.25-0.33 | |||
Cooling Water Temperature(3) | °C | 25 | |||
Cooling Water Specification | / | Deionized water 2.5±0.5μS/cm,pH-value 5.5- 8,filter<5μm |
(1) Data measured under operation at nominal output power @25°C.
(2) A non-condensing environment is required for operation and storage.
(3) Operating temperature defined by the package case. Acceptable operating range is 20°C-30°C,but performance may vary.
(4) The data above are for reference only. For specific data, please refer to the delivery package data.
(5) Other wavelengths and configurations on customer request.